Bitmain Antminer S19 Pro Hydro Specifications

Bitmain Antminer S19 Pro Hydro specifications, computing power consumption, power supply, usage environment, and other related information are shown in the tables:

Product GlanceValue
VersionS19 Pro Hydro
Model208-A
Crypto Algorithm/CoinsSHA256/BTC/BCH
Hashrate, TH/s184 ± 3%
Power on [email protected]℃, Watt5428 ± 5%
Power Efficiency on Wall @Tj65°C, J/TH29.5 ± 5%
Detailed CharacteristicsValue
Power Supply
Power Supply AC Input Voltage, Volt(1-1)342~418
Power Supply AC Input Frequency Range,Hz47~63
Power Supply AC Input Current, Amp(1-2)30(1-3)
Hardware Configuration
Network Connection ModeRJ45 Ethernet 10/100M
Miner Size (Length*Width*Height, w/o package), mm(2-1)336*175.5*208
Miner Size (Length*Width*Height, with package), mm570*316*430
Net Weight, kg(2-2)13.0
Gross Weight, kg15.6
Environment Requirements
Operation Temperature, °C0~40
Storage Temperature, °C-20-70
Operation Humidity(non-condensing), RH10~90%
Operation Altitude, m(3-1)≤2000
Product GlanceValue
VersionS19 Pro Hydro
Model208-A
Crypto Algorithm/CoinsSHA256/BTC/BCH
Hashrate, TH/s177 ± 3%
Power on [email protected]℃, Watt5222 ± 5%
Power Efficiency on Wall @Tj65°C, J/TH29.5 ± 5%
Detailed CharacteristicsValue
Power Supply
Power Supply AC Input Voltage, Volt(1-1)342~418
Power Supply AC Input Frequency Range,Hz47~63
Power Supply AC Input Current, Amp(1-2)30(1-3)
Hardware Configuration
Network Connection ModeRJ45 Ethernet 10/100M
Miner Size (Length*Width*Height, w/o package), mm(2-1)336*175.5*208
Miner Size (Length*Width*Height, with package), mm570*316*430
Net Weight, kg(2-2)13.0
Gross Weight, kg15.6
Environment Requirements
Operation Temperature, °C0~40
Storage Temperature, °C-20-70
Operation Humidity(non-condensing), RH10~90%
Operation Altitude, m(3-1)≤2000
Product GlanceValue
VersionS19 Pro Hydro
Model208-A
Crypto Algorithm/CoinsSHA256/BTC/BCH
Hashrate, TH/s170 ± 3%
Power on [email protected]℃, Watt5015 ± 5%
Power Efficiency on Wall @Tj65°C, J/TH29.5 ± 5%
Detailed CharacteristicsValue
Power Supply
Power Supply AC Input Voltage, Volt(1-1)342~418
Power Supply AC Input Frequency Range,Hz47~63
Power Supply AC Input Current, Amp(1-2)30(1-3)
Hardware Configuration
Network Connection ModeRJ45 Ethernet 10/100M
Miner Size (Length*Width*Height, w/o package), mm(2-1)336*175.5*208
Miner Size (Length*Width*Height, with package), mm570*316*430
Net Weight, kg(2-2)13.0
Gross Weight, kg15.6
Environment Requirements
Operation Temperature, °C0~40
Storage Temperature, °C-20-70
Operation Humidity(non-condensing), RH10~90%
Operation Altitude, m(3-1)≤2000
Product GlanceValue
VersionS19 Pro Hydro
Model208-A
Crypto Algorithm/CoinsSHA256/BTC/BCH
Hashrate, TH/s169.5 ± 3%
Power on [email protected]℃, Watt5000 ± 5%
Power Efficiency on Wall @Tj65°C, J/TH29.5 ± 5%
Detailed CharacteristicsValue
Power Supply
Power Supply AC Input Voltage, Volt(1-1)342~418
Power Supply AC Input Frequency Range,Hz47~63
Power Supply AC Input Current, Amp(1-2)30(1-3)
Hardware Configuration
Network Connection ModeRJ45 Ethernet 10/100M
Miner Size (Length*Width*Height, w/o package), mm(2-1)197*208.6*412
Miner Size (Length*Width*Height, with package), mm570*316*430
Net Weight, kg(2-2)15.8
Gross Weight, kg17.7
Environment Requirements
Operation Temperature, °C0~40
Storage Temperature, °C-20-70
Operation Humidity(non-condensing), RH10~90%
Operation Altitude, m(3-1)≤2000
Product GlanceValue
VersionS19 Pro Hydro
Model208-A
Crypto Algorithm/CoinsSHA256/BTC/BCH
Hashrate, TH/s163 ± 3%
Power on [email protected]℃, Watt4809 ± 5%
Power Efficiency on Wall @Tj65°C, J/TH29.5 ± 5%
Detailed CharacteristicsValue
Power Supply
Power Supply AC Input Voltage, Volt(1-1)342~418
Power Supply AC Input Frequency Range,Hz47~63
Power Supply AC Input Current, Amp(1-2)30(1-3)
Hardware Configuration
Network Connection ModeRJ45 Ethernet 10/100M
Miner Size (Length*Width*Height, w/o package), mm(2-1)336*175.5*208
Miner Size (Length*Width*Height, with package), mm570*316*430
Net Weight, kg(2-2)13.0
Gross Weight, kg15.6
Environment Requirements
Operation Temperature, °C0~40
Storage Temperature, °C-20-70
Operation Humidity(non-condensing), RH10~90%
Operation Altitude, m(3-1)≤2000
Product GlanceValue
VersionS19 Pro Hydro
Model208-A
Crypto Algorithm/CoinsSHA256/BTC/BCH
Hashrate, TH/s162 ± 3%
Power on [email protected]℃, Watt4780 ± 5%
Power Efficiency on Wall @Tj65°C, J/TH29.5 ± 5%
Detailed CharacteristicsValue
Power Supply
Power Supply AC Input Voltage, Volt(1-1)342~418
Power Supply AC Input Frequency Range,Hz47~63
Power Supply AC Input Current, Amp(1-2)30(1-3)
Hardware Configuration
Network Connection ModeRJ45 Ethernet 10/100M
Miner Size (Length*Width*Height, w/o package), mm(2-1)197*208.6*412
Miner Size (Length*Width*Height, with package), mm570*316*430
Net Weight, kg(2-2)15.8
Gross Weight, kg17.7
Environment Requirements
Operation Temperature, °C0~40
Storage Temperature, °C-20-70
Operation Humidity(non-condensing), RH10~90%
Operation Altitude, m(3-1)≤2000
Product GlanceValue
VersionS19 Pro Hydro
Model208-A
Crypto Algorithm/CoinsSHA256/BTC/BCH
Hashrate, TH/s154.5 ± 3%
Power on [email protected]℃, Watt4558 ± 5%
Power Efficiency on Wall @Tj65°C, J/TH29.5 ± 5%
Detailed CharacteristicsValue
Power Supply
Power Supply AC Input Voltage, Volt(1-1)342~418
Power Supply AC Input Frequency Range,Hz47~63
Power Supply AC Input Current, Amp(1-2)30(1-3)
Hardware Configuration
Network Connection ModeRJ45 Ethernet 10/100M
Miner Size (Length*Width*Height, w/o package), mm(2-1)197*208.6*412
Miner Size (Length*Width*Height, with package), mm570*316*430
Net Weight, kg(2-2)15.8
Gross Weight, kg17.7
Environment Requirements
Operation Temperature, °C0~40
Storage Temperature, °C-20-70
Operation Humidity(non-condensing), RH10~90%
Operation Altitude, m(3-1)≤2000


*Notes
:

(1-1)Caution: Wrong input voltage may probably cause miner damaged

(1-2)Maximum power consumption on the wall: 40°C ambient temperature, 0m above sea level

(1-3)Three-phase AC input, 10A per wire

(2-1)Including power supply dimensions

(2-2) Including the weight of the power supply

(3-1) For every 300 meters of altitude when the working altitude of the mining machine is between 900 and 2000 meters, the maximum operating temperature will drop by 1 degree Celsius.

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top